Section Contents
5.5
BEST BY FARR
TM
14 1/2" Closed Mouth Trailer-Mounted Bucking Unit
Technical Manual
E. TONG WILL NOT DEVELOP SUFFICIENT TORQUE
1. Malfunctioning relief valve on unit or tong.
a. POSSIBLE PROBLEM: Relief pressure set too low.
SOLUTION: Increase setting. To check, block the oil line beyond the relief valve and
determine pressure with a gauge.
b. POSSIBLE PROBLEM: Valve is stuck.
SOLUTION: Check for contamination of oil that may inhibit the way the valve actuates.
Remove valve and clean, ensuring that the valve spring operates smoothly.
c. POSSIBLE PROBLEM: Valve is leaking.
SOLUTION: Check valve seat for scouring. Check oil seals. Check for particles stuck
under the valve system.
2. POSSIBLE PROBLEM: Worn or damaged pump parts.
SOLUTION: Inspect and clean, replace all worn or broken parts.
3. POSSIBLE PROBLEM: Pump speed too slow.
SOLUTION: Check motor speed.
4. POSSIBLE PROBLEM: Fluid viscosity too high.
SOLUTION: Pump may not prime if fluid is too heavy. Replace with proper viscosity fluid.
5. POSSIBLE PROBLEM: Viscosity of fluid too low.
SOLUTION: System may overheat. Replace with proper viscosity fluid.
6. POSSIBLE PROBLEM: Fluid by-passed to reservoir.
SOLUTION: Check relief valve for proper operation. Check directional valve. Neutral posi-
tion should return fluid directly to the reservoir.
7. POSSIBLE PROBLEM: Worn or damaged tong motor causing slippage.
SOLUTION: Replace or repair worn or damaged parts.
8. POSSIBLE PROBLEM: Damaged bearings or gears causing excessive drag.
SOLUTION: Repair or replace worn parts.
9. POSSIBLE PROBLEM: Poor hydraulic pressure at the tong or excessive back pressure in
the return line.
SOLUTION: Restriction in line between power unit and tong. Inspect integrity of self-
sealing couplings.
10. POSSIBLE PROBLEM: Defective torque gauge or load cell.
SOLUTION: Replace defective components. Ensure dampening screw has been adjusted.
Ensure gauge has been calibrated to proper torque arm length.
Troubleshooting